SMP2081 Temperature and pressure dual output pressure sensor_Xian Sensors limited company

HOME > PRODUCT > Pressure sensor core

Pressure sensor core

SMP2081 Temperature and pressure dual output pressure sensor

2017-12-06Page views:2155 Times

●Outline structure(unit: mm)



                             <20MPa                                                                                                                                ≥20MPa


●Parameters

Construction Condition

Diaphragm material

SS 316L

Housing material

SS 316L

Pin Wire

Kovar/100mm silicone rubber wire

Back pressure tube

SS 316L (gauge and negative pressure only)

Seal ring

Nitrile rubber

Electrical Condition

Power supply

1.5mADC

Impedance input

2.5kΩ~5kΩ

Impedance output

2.5kΩ~5kΩ

Response

(10%~90%):<1ms

Insulation resistance

100MΩ,100V DC

Overpressure

2 times FS

Environmental Condition

Media applicability

Fluid which has no corrosion on stainless steel and nitrile rubber

Shock

No change at 10gRMS(202000)Hz

Impact

100g11ms

Position

Deviate 90° from any direction, zero change≤±0.05%FS

Basic Condition

Environment temperature

25±1

Humidity

50%±10%RH

Atmospheric pressure

(86~106) kPa

Power supply

1.5±0.0015mA  DC


●Installation recommended(unit::mm):




Pin

Electrical  definition

Wire color

4

+OUT

Red

10

 OUT

Yellow

11

IN

Yellow

12

+IN

Black

13

Temperature sensing lead 1

White

14

Temperature sensing lead 2

 White



●Parameter

Item

Min.

Typ.

Max.

Unit

Linearity

±0.15

±0.25

%FS,BFSL

Repeatability

±0.05

±0.075

%FS

Hysteresis

±0.05

±0.075

%FS

Zero output

±2.0

±2.0

mV DC

FS output

45

100

mV DC

Temperature output

PT100 Resistance output

Compensated temp. range

0~70

Working temp. range

-40~125

Storage temp. range

-55~150

Zero temp. error

±0.75

±1.0

%FS@ 25

Full temp. error

±0.75

±1.0

%FS@25

Long term stability error

 

±0.0

 

%FS/year

Note1. The above performance indicators are tested under the benchmark conditions

     2. The temperature range for temperature drift test is the compensation temperature range